| Model 200 |
Model 400 |
Model 600 |
Model 900 |
Model 1500 |
| Elevator hoistway opening sizes |
| 42 inches and 48 inches only |
Up to 5 feet wide |
Custom sizes available |
Up to 7 feet wide |
6-12 feet wide |
| Mounting height |
| Up to 10 feet high |
Up to 10 feet high |
Up to 10 feet high |
Up to 9 feet, 10 inches high |
Up to 12 feet high |
| Unit return sizes (projection from wall) |
| Standard return available: 1 inch |
Standard returns available: 1/2 inch, 3/4 inch, and 1 inch |
Standard returns available: 1/2 inch, 3/4 inch and 1 inch. Custom returns available as well |
Standard return available: 3/4 inch |
N/A |
| Housing dimensions |
| Housing widths: 55 and 64 inches. Height: 10.5 inches. Depth: 9 inches (plus
return) |
Housing widths: 55, 64 and 73 inches. Height: 10.5 inches. Depth:
9 inches (plus return) |
Housing widths: 52, 56, and 63 inches. Height: 13 inches std or
9 inches with side mount motor. Depth: 7.5 inches (plus return) |
Housing widths : 94.25 inches. Height : 16.25 inches. Depth: 11 inches |
Housing widths: custom 71.875 to 143.875 inches. Height: 7 or 7.25 inches, plus 5.25 inch battery depth |
| Unit electronic control |
| In electrical box mounted inside the housing |
In electrical box mounted inside the housing |
In separate electrical box that can be mounted next to unit housing or up to thirty conduit feet away |
In electrical box mounted inside the housing |
In electrical box mounted inside the housing |
| Emergency power source |
| No internal emergency power source. Unit is fail safe and will deploy if primary power disrupted for more than 10 seconds. Unit can be connected to emergency power |
No internal emergency power source. Unit is fail safe and will deploy if primary power is disrupted for more approximately 8 seconds. Unit can also be connected to emergency power |
Each unit has battery that can power unit for up to ten days |
Each unit has a battery that powers the unit for up to ten days |
Each unit has a battery that powers the unit for up to ten days |
| Protection from temporary power failures |
| A brief delay avoids nuisance deploys |
A brief delay avoids nuisance deploys |
Emergency power source takes over if AC power is disrupted |
Emergency power source takes over if AC power is disrupted |
Emergency power source takes over if AC power is disrupted |
| Curtain rewind switch |
| Yes, located on both sides of curtain |
Yes, located on both sides of curtain |
Yes, located on both sides of curtain |
Yes, located on both sides of curtain |
No |
| Curtain deploy switch |
| Yes, located on controls inside housing |
Yes, located on controls inside housing |
Yes, key activated from wall switch |
Yes, located on controls inside housing |
Yes, mounted on opposing walls |
| Cove bases required |
| No |
No |
No, for elevator openings up to 60 inches. Yes, for opening sizes beyond 60 inches |
Yes |
N/A |
| Stainless steel auxiliary rails |
| Yes, for all units. Rails can be painted to match in field |
Rails optional, if elevator frame is ferrous and at least 2" wide. If rails are used, they can be painted to match or left unpainted |
Rails optional, if elevator frame is ferrous and at least 2" wide. If rails are used, they can be painted to match or left unpainted |
Yes, for all units |
N/A |