Elevator hoistway opening sizes
42 inches and 48 inches only
|
Elevator hoistway opening sizes
Up to five feet wide
|
Elevator hoistway opening sizes
Custom sizes available |
Mounting height
Up to 10 feet high |
Mounting height
Up to 10 feet high
|
Mounting height
Up to 10 feet high
|
Unit return sizes (projection from wall)
One inch
|
Unit return sizes (projection from wall)
Standard returns available: 1/2?, 3/4?, and 1 ?.
|
Unit return sizes (projection from wall)
Standard returns available: 1/2?. 3/4? and 1?. Custom returns available as well.
|
Housing dimensions
Housing width: 55 and 64 inches Height: 10.5 inches Depth: 9 inches (plus
return) |
Housing dimensions
Housing widths:55 inches, 64 inches, 73 inches Height: 10.5 inches Depth:
9 inches (plus return) |
Housing dimensions
Housing widths: 52 inches, 56 inches, 63 inches Height: 13 inches std or
9 inches with side mount motorDepth: 7.5 inches (plus return) |
Unit electronic control
In electrical box mounted inside the housing
|
Unit electronic control
In electrical box mounted inside the housing
|
Unit electronic control
In separate electrical box that can be mounted next to unit housing or up to thirty conduit feet away
|
Emergency power source
No internal emergency power source. Unit is fail safe secure and will deploy if primary power disrupted for more than 10 seconds. Unit can be connected to emergency power.
|
Emergency power source
No internal emergency power source. Unit is fail safe secure and will deploy if primary power is disrupted for more approximately 8 seconds. Unit can also be connected to emergency power.
|
Emergency power source
Each unit has battery that can power unit for up to ten days
|
Protection from temporary power failures
A brief delay avoids nuisance deploys.
|
Protection from temporary power failures
A brief delay avoids nuisance deploys.
|
Protection from temporary power failures
Emergency power source takes over if AC power is disrupted.
|
Screen rewind switch
Yes, located on both sides of screen
|
Screen rewind switch
Yes, located on both sides of screen
|
Screen rewind switch
Yes, located on both sides of screen
|
Screen deploy switch
Yes, located on controls inside housing
|
Screen deploy switch
Yes, located on controls inside housing
|
Screen deploy switch
Yes, key activated from wall switch
|
Cove bases required?
No
|
Cove bases required?
No
|
Cove bases required?
No, for elevator openings up to 48 inches. Yes, for opening sizes beyond 48 inches.
|
Stainless steel auxiliary rails
Yes, for all units. Rails can be painted to match in field.
|
Stainless steel auxiliary rails
Rails optional, if elevator frame is ferrous and at least 2? wide. If rails are used, they can be painted to match or left unpainted.
|
Stainless steel auxiliary rails
Rails optional, if elevator frame is ferrous and at least 2? wide. If rails are used, they can be painted to match or left unpainted.
|