> ENTER YOUR ZIP CODE HERE:
 

      > NEED TO LOCATE A ZIP CODE?
     


The Smoke Guard System is available in three different models. In order to determine which Smoke Guard System model best suits your project, we suggest that you consult with the Smoke Guard System distributor in your area.

Elevator hoistway opening sizes
42 inches and 48 inches only
Elevator hoistway opening sizes
Up to five feet wide
Elevator hoistway opening sizes
Custom sizes available
Mounting height
Up to 10 feet high
Mounting height
Up to 10 feet high
Mounting height
Up to 10 feet high
Unit return sizes (projection from wall)
One inch
Unit return sizes (projection from wall)
Standard returns available: 1/2?, 3/4?, and 1 ?.
Unit return sizes (projection from wall)
Standard returns available: 1/2?. 3/4? and 1?. Custom returns available as well.
Housing dimensions
Housing width: 55 and 64 inches Height: 10.5 inches Depth: 9 inches (plus return)
Housing dimensions
Housing widths:55 inches, 64 inches, 73 inches Height: 10.5 inches Depth: 9 inches (plus return)
Housing dimensions
Housing widths: 52 inches, 56 inches, 63 inches Height: 13 inches std or 9 inches with side mount motorDepth: 7.5 inches (plus return)
Unit electronic control
In electrical box mounted inside the housing
Unit electronic control
In electrical box mounted inside the housing
Unit electronic control
In separate electrical box that can be mounted next to unit housing or up to thirty conduit feet away
Emergency power source
No internal emergency power source. Unit is fail safe secure and will deploy if primary power disrupted for more than 10 seconds. Unit can be connected to emergency power.
Emergency power source
No internal emergency power source. Unit is fail safe secure and will deploy if primary power is disrupted for more approximately 8 seconds. Unit can also be connected to emergency power.
Emergency power source
Each unit has battery that can power unit for up to ten days

Protection from temporary power failures
A brief delay avoids nuisance deploys.

Protection from temporary power failures
A brief delay avoids nuisance deploys.

Protection from temporary power failures
Emergency power source takes over if AC power is disrupted.

Screen rewind switch
Yes, located on both sides of screen

Screen rewind switch
Yes, located on both sides of screen

Screen rewind switch
Yes, located on both sides of screen

Screen deploy switch
Yes, located on controls inside housing

Screen deploy switch
Yes, located on controls inside housing

Screen deploy switch
Yes, key activated from wall switch

Cove bases required?
No

Cove bases required?
No

Cove bases required?
No, for elevator openings up to 48 inches. Yes, for opening sizes beyond 48 inches.
Stainless steel auxiliary rails
Yes, for all units. Rails can be painted to match in field.
Stainless steel auxiliary rails
Rails optional, if elevator frame is ferrous and at least 2? wide. If rails are used, they can be painted to match or left unpainted.
Stainless steel auxiliary rails
Rails optional, if elevator frame is ferrous and at least 2? wide. If rails are used, they can be painted to match or left unpainted.